Manual - V2000-c Rfid Access Control User

| Problem | Likely Cause | Solution | | :--- | :--- | :--- | | No LED / No beep | Power failure | Check 12V supply polarity. | | Card not working | Wrong frequency / Not added | Ensure card is 125KHz or 13.56MHz. | | Door won’t lock | Wiring to NC/COM reversed | Swap Green (NC) and White (COM) wires. | | Alarm always beeps | Door sensor open | Disable sensor (Command 22 0 #). |

In today's fast-paced world, security and access control have become a top priority for individuals and organizations alike. One of the most effective ways to ensure secure access to a premises or a specific area is by using RFID (Radio Frequency Identification) access control systems. The V2000-C RFID access control system is a popular and widely used solution that offers a high level of security, flexibility, and ease of use.

| Action | Command | |--------|---------| | Enter programming mode | *MasterCode# (e.g., *123456# ) | | Change master code | 00 NewCode# RepeatNewCode# | | Add RFID card | 11 CardNumber# (or present card after 11 ) | | Add PIN user (ID 1–200) | 12 UserID# PIN# | | Add card + PIN user | 13 UserID# → present card → enter PIN | | Delete single user | 14 UserID# | | Delete all users | 15# (use with caution) | | Set relay duration (1–60s) | 03 Seconds# | | Set door sensor mode (0=off,1=on) | 04 Mode# | | Exit programming | *# | V2000-c Rfid Access Control User Manual

This procedure will reset the system password only to the factory default 12345 . It will not delete your registered users. For a full reset, consult your specific device manual.

Enter Programming Mode -> Press 0 + [New 6-digit Code] + # + [Repeat New Code] + # . Adding Users (Card or Keyfob) Enter Programming Mode. Press 1 + [Read Card] + # . | Problem | Likely Cause | Solution |

Normally Open relay contact (used for fail-secure electric locks) COM (Grey): Common relay contact

To enter programming mode, you must use the . The default master code is usually 990101 or 123456 . Enter/Exit Programming Mode Press * + [Master Code] + # . (The LED will turn red/flash). Press * to exit programming mode at any time. Change the Master Code | | Alarm always beeps | Door sensor

| Terminal | Label | Connection | Wire Gauge (AWG) | | :--- | :--- | :--- | :--- | | 1 | +12V | Power Supply Positive (10-14V DC) | 18-22 | | 2 | GND | Power Ground / Common Negative | 18-22 | | 3 | NO | Normally Open (Magnetic Lock) | 18 | | 4 | COM | Common (Lock Relay) | 18 | | 5 | NC | Normally Closed (Electric Strike - Fail Secure) | 18 | | 6 | PUSH | Exit Button Signal (Short to GND to activate) | 22 | | 7 | SEN | Door Contact Sensor (Magnetic Reed Switch) | 22 | | 8 | AL+ | Alarm Output (+) | 22 | | 9 | AL- | Alarm Output (-) | 22 | | 10 | +12V | Reader Power (For external reader – rarely used) | 22 | | 11 | DATA0 | Wiegand Data 0 (For external reader) | 22 | | 12 | DATA1 | Wiegand Data 1 (For external reader) | 22 |