Caraflo V200 Shower Instructions ⇒

The V200 features an automatic safety stop mechanism (usually set at 38°C). This prevents accidental scalding, which is especially critical in mobile homes where water tank temperatures can spike. To achieve a temperature hotter than 38°C, press and hold the mechanical safety button on the handle while continuing to rotate the dial. 🧼 Routine Maintenance & Cleaning

: Always flush the supply pipework before fitting the mixer to prevent debris from damaging the thermostatic cartridge. Components

: Remove the shower hose from the mixer or lay the head in the tray to drain trapped water. Open Valves : Open the flow valve fully. caraflo v200 shower instructions

The Caraflo V200 is a popular, compact thermostatic mixer valve widely used in caravans, motorhomes, and boats. It is highly valued for its ability to maintain a constant water temperature despite fluctuations in supply pressure.

| Problem | Possible Cause | Solution | | :--- | :--- | :--- | | | Power source issue (dead batteries) or no water supply. | Replace batteries (usually AA inside the control box) or check main water valves. | | Water is too cold | Hot water supply cut off or inlet filters blocked. | Check if the water heater is working. Clean the hot water inlet strainer. | | Temperature fluctuates | Unbalanced water pressure or dirty thermostatic cartridge. | Ensure no other appliances (washing machine/toilet) are using water simultaneously while showering. Clean cartridge. | | LED Display fading | Low battery voltage. | Replace batteries immediately to prevent the valve from sticking in the "open" position. | | Water drips after shut off | Residual water in the pipe. | This is normal for a few seconds. If it persists, the internal solenoid valve may need cleaning or replacement. | The V200 features an automatic safety stop mechanism

The is a thermostatic mixer shower designed for built-in or exposed valve installations . It maintains stable water temperature even when other taps are used, preventing scalding or sudden cold shocks.

15mm compression or 1/2" BSP threads (depending on the specific sub-model variant) Inlet Centers: 150mm standard pipe spacing Pre-Installation Requirements 🧼 Routine Maintenance & Cleaning : Always flush

A hidden compartment hissed open, revealing four glass vials labeled: Eucalyptus Grenade, Smoked Birch, Wet Cardboard, and Regret (Limited Edition). He ignored this.

Before using the unit, ensure the following safety measures are observed to prevent injury or damage to the unit:

With proper care and maintenance, your Caraflo V200 will continue to deliver safe, consistent showers for many seasons to come.